Introduction

Recent interest in wearable electronics has intensified due to its promising potential for practical usability1,2,3,4. Many advancements, including structural engineering and innovative material design, have paved the way for soft electronics, such as skin-mountable and bio-implantable devices3,4,5,6,7. Particularly, studies in intrinsically stretchable electronic materials and rubbery composites have played a crucial role in developing fully soft organic electronic devices that enable intimate mounting on skin or implanting into the human body3,6,7. While such material development has been a primary focus, the interface between components is indeed critical for the significant advancement of high-performance fully soft organic electronics8,9,10. The contact resistance (RC), mainly induced by the difference between Fermi levels (EF) of metal electrodes and energy levels of semiconductors, obstructs charge carrier transport at the interface, hampering field-effect mobility in organic transistors9,10. However, interfacial engineering for minimizing RC in fully soft organic transistors has been overlooked, although efforts in reducing it for rigid and flat transistors have been studied8,11,12, which is not compatible with devices that are made out of only soft components. Thus, there is an urgent need in the development of the appropriate approach to form better interface for fully soft organic electronics.

The recently developed fully soft organic transistors, which employ silver nanowires-embedded PDMS (AgNWs/PDMS) as a soft electrode, are promising due to their exceptional electrical and mechanical properties. However, they face an inherent challenge regarding the energy barrier between silver (EF,Ag is from −4.26 eV), and typical p-type organic semiconductors (EHOMO is from −4.90 to −5.50 eV)13,14. A common solution, the galvanic replacement of the AgNWs surface with gold (EF,Au is −5.09 eV), ensures ohmic contact between soft electrodes and the organic semiconductor15,16,17. Nonetheless, this method often leads to non-uniform gold particulation on AgNWs due to the vigorous redox reaction18,19. Particularly, incomplete gold coverage and a rough surface can result in a large RC in soft transistors19. Moreover, inconsistent gold coverage on AgNWs within the AgNWs/PDMS electrodes limits their application in soft biosensors due to the chemical instability of silver20. Therefore, a more promising approach would involve achieving a complete and uniform gold coating through a simple process.

In this study, we report an effective approach for gold coating on exposed AgNWs in AgNWs/PDMS electrodes, aimed at reducing the RC in fully soft organic transistors. The key concept in this approach is the controlled deceleration of the galvanic replacement reaction, achieved by employing HAuCl4 solution with added NaCl. The excess Cl ions, dissociated from NaCl, play a crucial role in moderating the redox reaction according to Le Chatelier’s principle, reducing the reduction potential difference, and preventing AgCl precipitation. Although many studies have reported on the effects of NaCl in galvanic replacement, none have applied these findings to soft electronics; instead, most have all focused on the formation of nano-sized materials21,22,23. This study revealed a direct correlation between the concentration of NaCl (CNaCl) in the HAuCl4 solution and various properties, including the quality of gold coating, RC, and μFE of the transistor. Significantly, our approach of achieving a uniform gold coating on AgNWs led to a substantial reduction in RC, thus accomplishing the high-performance fully soft organic transistors, with an average mobility of 13.09 cm2·V1·s1, and the highest mobility of 21.87 cm2·V1·s1. Furthermore, the uniform and reliable gold coating on AgNWs of AgNWs/PDMS has shown further advantages in enzyme-based soft glucose sensors, particularly by offering enhanced chemical resistance to H2O2, thereby ensuring reliable sensing capability.

Results

Au-coated AgNWs/PDMS soft electrodes for soft organic transistors

Figure 1a shows an 8 × 8 array of fully soft organic transistors fabricated using Au-coated AgNWs/PDMS source, drain electrodes, an AgNWs/PDMS gate electrode, a soft organic semiconductor, and ion gel gate dielectrics. Conventional Au deposition on AgNWs/PDMS typically leads to unfavorable charge transport between the organic semiconductor and soft electrodes, as shown in Fig. 1b. In contrast, a uniform Au coating on AgNWs/PDMS enables efficient charge transport (Fig. 1c), thereby reducing RC and enhancing device performance, such as charge carrier mobility. Therefore, achieving uniform Au coating on AgNWs/PDMS is crucial for the high performance of fully soft organic transistors. Figure 1d schematically illustrates the galvanic replacement process for Au coating on the exposed AgNWs of AgNWs/PDMS electrodes, comparing the use of HAuCl4 solution with and without NaCl. The preparation of AgNWs/PDMS electrodes is detailed in the Experimental Section. The conventional Au coating via galvanic replacement using HAuCl4 solution results in an intense reaction that creates a particulate and non-uniform Au layer, whereas the inclusion of NaCl in the solution facilitates a uniform and complete coverage of Au on AgNWs/PDMS electrodes, as shown in the insets of the scanning electron microscopic (SEM) images in Fig. 1d. The detailed kinetics of the NaCl effect on the galvanic replacement process for the soft electrode will be discussed in the following section.

Fig. 1: Au-coated AgNWs/PDMS soft electrodes prepared by galvanic replacement.
figure 1

a An optical image of the 8 × 8 fully soft organic transistors array. Inset is the schematic exploded view of the single fully soft organic transistor. b, c Schematic of the charge injection between the organic semiconductor and particulate Au-coated AgNWs/PDMS electrodes (b), and uniform Au-coated AgNWs/PDMS electrodes (c). d Schematic of the galvanic replacement process of AgNWs/PDMS electrodes using HAuCl4 solution in the presence and absence of NaCl. Insets are SEM images of the soft electrode under each condition.

The effect of NaCl on Au coating of soft AgNWs/PDMS electrodes

Figure 2a, b exhibit SEM images of exposed AgNWs of AgNWs/PDMS electrodes over time during the galvanic replacement process, comparing the use of HAuCl4-only solution and the solution containing 50 mM NaCl. In the case of the galvanic replacement with the HAuCl4-only solution, no significant change was observed after 2 min, suggesting rapid reaction completion, and resulting in particulate and non-uniform Au coating on AgNWs. On the other hand, the HAuCl4 solution containing 50 mM NaCl completed the reaction in approximately 40 min, achieving uniform Au coverage. It is noted that the NaCl concentration (CNaCl) in the HAuCl4 solution is optimized at 50 mM due to negligible changes at higher concentrations, as shown in Supplementary Fig. 1. In addition, NaCl does not cause corrosion or structural damage to the AgNWs/PDMS electrode during the galvanic replacement because the short treatment period is not sufficient to have an adverse effect on the AgNWs (Supplementary Fig. 2). Optical microscopic (OM) images also corroborate that complete and uniform Au coverage is saturated at the CNaCl of 50 mM (Supplementary Fig. 3). Importantly, HAuCl4 concentration (C (HAuCl4)) does not impact the Au coating on AgNWs even after 60 min, as shown in Supplementary Fig. 4, underscoring the critical role of NaCl in achieving uniform Au formation on AgNWs.

Fig. 2: Reaction kinetics of Au coating process.
figure 2

Time-dependent SEM images of the Au-coated AgNWs/PDMS electrodes prepared by galvanic replacement using 0.5 mM HAuCl4 solution without NaCl (a), and with 50 mM NaCl (b). c Cyclic voltammograms of 0.5 mM HAuCl4 solution without, and with various concentrations of NaCl. Schematic of the Au-coated AgNWs/PDMS electrodes using 0.5 mM HAuCl4 solution without NaCl (d), and with 50 mM NaCl (f). EDS elements mapping of the Au-coated AgNWs/PDMS electrodes using 0.5 mM HAuCl4 solution without NaCl (e) and with 50 mM NaCl (g).

The mechanism for uniform Au coating using HAuCl4 with NaCl is attributed to two key phenomena: (1) slowed reaction rate from Le Chatelier’s principle and a negative shift in reduction potential, and (2) prevention of AgCl precipitation through soluble complex formation. The reaction, driven by the reduction potential difference between AuCl4 and Ag+, is described by equation (1):

$$\begin{array}{l}3{\rm{Ag}}({\rm{s}})+{{\rm{AuCl}}}_{4}^{-}({\rm{aq}})\to {\rm{Au}}({\rm{s}})+{3{\rm{Ag}}}^{+}({\rm{aq}})\\\qquad\quad+\space{4{\rm{Cl}}}^{-}({\rm{aq}})\to {\rm{Au}}({\rm{s}})+3{\rm{AgCl}}({\rm{s}})+{{\rm{Cl}}}^{-}({\rm{aq}})\end{array}$$
(1)

In the presence of NaCl, excess Cl shifts the equilibrium leftward by Le Chatelier’s principle, slowing the galvanic replacement reaction24,25. In addition, the reduction potential difference between AuCl4/Au0 and Ag+/Ag0 is closely related to the reaction rate18. As shown in the cyclic voltammogram in Fig. 2c, the cathodic scan reveals a peak at 0.56 V versus Ag/AgCl for reduction to Au0, shifting to 0.35 V with 50 mM NaCl, indicating a reduced galvanic replacement driving force. Interestingly, while CNaCl does not significantly affect the reduction potential of AuCl4/Au0, anodic peaks shift negatively with higher CNaCl, implying easier oxidation of Au0 and equilibrium shift towards AuCl4 formation. Furthermore, AgCl precipitation intensifies particulate Au formation19, mitigated by soluble Ag complex (AgCl2) formation in excess Cl conditions19,26, as evidenced by energy dispersive X-ray spectroscopy (EDX) analysis showing concentrated Cl distribution on particulate Au (Supplementary Fig. 5).

The morphologies of Au-coated AgNWs prepared using HAuCl4-only solution and the solution containing 50 mM NaCl are investigated. The HAuCl4 solution without NaCl leads to the formation of particulate Au and results in severe AgNWs loss as shown in Fig. 2d, e, and Supplementary Fig. 6. This originates from the reaction stoichiometry and rapid electrochemical reaction rate. In contrast, the slower reaction induced by adding 50 mM NaCl to the HAuCl4 solution results in galvanic replacement occurring primarily at the outer atoms of the AgNWs, as shown in Fig. 2f, g18. This leads to a predominantly uniform Au coating on the AgNWs and the formation of partially hollow structured Au-coated AgNWs, which do not compromise the electrical properties (Supplementary Fig. 7).

Electrical properties of organic transistors based on Au-coated AgNWs/PDMS electrodes

We firstly investigated the RC in organic transistors using Au-coated AgNWs/PDMS electrodes prepared by HAuCl4 solutions containing various CNaCl. Figure 3a illustrates the organic transistors, fabricated with PTB7-Th and ion gel as the organic semiconductor and gate dielectric, respectively27. In particular, PTB7-Th, selected for its significantly negative highest occupied molecular orbital (HOMO) level (EHOMO = − 5.24 eV) compared to the Fermi level of silver28, highlights the substantial RC in the organic transistor and exhibits clear RC change depending on the morphologies of Au-coated AgNWs/PDMS (Fig. 3b, c). The detailed materials preparation and device fabrication process are described in the Experimental Section and schematically illustrated in Supplementary Fig. 8.

Fig. 3: Characterization of Au-coated AgNWs/PDMS electrodes-based p-type organic transistors.
figure 3

a Schematic exploded view (left), and an optical image (right) of the Au-coated AgNWs/PDMS electrodes-based p-type organic transistor. b A molecular structure of PTB7-Th. c Energy levels of the PTB7-Th, gold, and silver. d RCW of the organic transistors prepared using 0.5 mM HAuCl4 solution varying CNaCl. Data are presented as mean values ± 1 standard deviation (s.d.) based on measurements from 30 devices. e Representative transfer characteristics of the organic transistors based on the Au-coated AgNWs/PDMS electrodes prepared using 0.5 mM HAuCl4 solution varying CNaCl. f The calculated μFE of the organic transistors based on the Au-coated AgNWs/PDMS electrodes prepared using 0.5 mM HAuCl4 solution varying CNaCl. Data are presented as mean values ± 1 s.d. based on measurements from 10 devices.

The RC of the PTB7-Th based organic transistors based on Au-coated AgNWs/PDMS electrodes prepared by various CNaCl in 0.5 mM HAuCl4 solution for the galvanic replacement was investigated using the transfer length method (TLM)17. The channel length (LCH) of devices varied from 30 to 400 μm, while the channel width (WCH) was fixed at 1250 μm. The width-normalized ON resistances (RONW) depending on LCH of devices in different conditions are plotted in Supplementary Fig. 9, and RCW for each condition is extracted from these plots. The details for TLM are described in Supplementary Note 1. As shown in Fig. 3d, RCW of devices significantly decreased with 50 mM CNaCl in the HAuCl4 solution (387 ± 72 Ω∙cm) compared to devices using pristine AgNWs/PDMS electrode (849 ± 162 Ω∙cm) and those with Au coating from HAuCl4-only (655 ± 147 Ω∙cm) solution. Negligible RCW change at higher CNaCl suggests saturated Au coverage above CNaCl of 50 mM, corresponding to the observed morphological trends. This result suggests that using NaCl-containing HAuCl4 solution for the galvanic replacement of Au coating on AgNWs/PDMS could be an effective approach to enhance charge carrier transport between the soft electrode and the organic semiconductor.

We further evaluated the electrical characteristics of the device using Au-coated AgNWs/PDMS electrodes prepared by galvanic replacement with varying CNaCl. For consistent comparison, LCH and WCH for all devices were fixed at 100 and 1250 μm, respectively. The representative output characteristics of the organic transistors under different conditions are shown in Supplementary Fig. 10, where all devices exhibited typical p-channel behavior. The hysteresis behavior of the transistors presented in Supplementary Fig. 11 is comparable to that reported for ion-gated transistors29. As shown in Fig. 3e and Supplementary Fig. 12, obvious performance differences were observed in the devices made with the solutions containing varying CNaCl. The ON current of the devices was clearly enhanced as the CNaCl in the HAuCl4 solution increased and saturated from 50 mM of CNaCl. The mobility (μFE), subthreshold swing (s.s.), and threshold voltage (VTH) of the transistors were extracted from the transfer curves as described in Supplementary Note 2. As plotted in Fig. 3f, the devices utilizing AgNWs/PDMS electrodes without and with Au coating (using CNaCl = 0 mM) showed the average μFE of 1.30 ± 0.89 and 2.42 ± 0.62 cm2·V1·s1, respectively, while those using 50 mM CNaCl achieved an average μFE of 7.45 ± 0.64 cm2·V1·s1. This μFE trend correlates with RC change. Furthermore, the subthreshold swing (s.s.) decreased from 325.21 ± 35.48 mV/dec in devices with Au-coated AgNWs/PDMS electrodes prepared without NaCl to 200.19 ± 37.69 mV/dec in those prepared with 50 mM CNaCl (Supplementary Fig. 13a). This reduction is attributed to the enhanced charge carrier injection efficiency between the semiconductor and electrode, facilitated by uniform Au coating on AgNWs/PDMS by utilizing NaCl. However, as shown in Supplementary Fig. 13b, the threshold voltage (VTH) remained largely unchanged across devices, regardless of NaCl use. This is because of the inherently low operating voltage characteristic of the ion-gating operation in this organic transistor, which results in only minor and imperceptible variations in VTH. Similar performance enhancements in μFE were also observed in organic transistors based on another p-type organic semiconductor, poly(3-hexylthiophene-2,5-diyl) (P3HT), with a HOMO level of − 5.0 eV 30, as shown in Supplementary Fig. 14. These results underscore the versatility of our approach for organic transistors with AgNWs/PDMS electrodes.

Fully soft organic transistors

We demonstrated high-performance, fully soft organic transistors comprised entirely of soft materials, utilizing Au-coated AgNWs/PDMS electrodes prepared with a 0.5 mM HAuCl4 solution containing 50 mM NaCl. The soft electrode exhibits excellent robustness in its electrical characteristics under 80% mechanical strain with no obvious degradation of the Au coating, as shown in Supplementary Fig. 15. A polymer blend comprising PTB7-Th and PDMS, referred to as PTB7-Th/PDMS, was utilized as a soft organic semiconductor. This selection was driven by the significant performance degradation observed in transistors solely composed of PTB7-Th under a mechanical strain of 80% 31. Numerous cases involving blends of polar semiconducting polymers and non-polymeric insulating polymers exhibit phase separation, a phenomenon known as the confinement effect. This effect results in the formation of a continuously connected semiconductor network, as schematically illustrated in Fig. 4a32. The atomic force microscopic (AFM) images reveal clear lateral phase separation in PTB7-Th/PDMS (Fig. 4b) compared to the uniformly dispersed phase in PTB7-Th (Supplementary Fig. 16). It is known that the morphology of the PTB7-Th/PDMS blend, which is induced by strong intermolecular interactions, is mainly influenced by the dipole moment and planarity of the semiconductor molecule32. Indeed, PTB7-Th has a considerably large dipole moment of 5.25 D (Fig. 4c), which was estimated using density functional theory (DFT). However, the dihedral angles between neighboring benzodithiophene and thieno[3,4-b]thiophene units, obtained at 27.67° and 15.22° (Supplementary Fig. 17, indicate relatively low planarity compared to semiconductors with reported high planarity32. This suggests that it is the dipole moment, rather than the planarity, that primarily contributes to inducing confinement effects. It is noted that the DFT calculation employed the B3LYP/6-31 G (d,p) simulation model. This model was based on a dimer comprising two repeating units of the PTB7-Th backbone, where methyl groups were used instead of the bulky 2-ethylhexyl chains for simplification. The noticeable redshift of the 0 − 0 peak, along with the significant increase in the ratio of the 0 − 0 to 0 − 1 peaks in the UV-vis absorption spectrum of the PTB7-Th/PDMS film, indicates strong interchain π-π interactions arising from the confinement effect (Supplementary Fig. 18)33.

Fig. 4: High-performance fully soft organic transistors.
figure 4

a Schematic of the soft semiconducting PTB7-Th/PDMS composite. b AFM images of the PTBT-Th/PDMS composites in the height (left), and phase (right) modes. c Molecular electrostatic potential map and the dipole moment of the PTB7-Th. Sequential optical (d), and AFM height (e) images of the PTB7-Th under the various mechanical strains. Note that d is 190, 220, 250 from the left in (e). f An optical image of the 8 × 8 fully soft organic transistors array. Inset is the magnified optical image of a single device. g The μFE distribution of the high-performance fully soft organic transistors. Data are presented as mean values ± 1 s.d. based on measurements from 64 devices. h The comparison of the μ and maximum stretchability with the reported fully soft organic transistors. Transfer characteristics of the fully soft organic transistors under the strains parallel (i), and perpendicular (j) to the channel length direction. k μFE and VTH changes of the fully soft organic transistors under the strains parallel (top), and perpendicular (bottom) to the channel length direction. Transfer characteristics of the fully soft organic transistors after the repetitive strains parallel (l), and perpendicular (m) to the channel length direction. n μFE and VTH changes of the fully soft organic transistors after the repetitive strains parallel (top), and perpendicular (bottom) to the channel length direction.

The mechanical robustness of the PTB7-Th/PDMS film was confirmed by OM and AFM images. Both the pristine PTB7-Th and the PTB7-Th/PDMS films exhibit no obvious damage under a mechanical strain of up to 80%, as observed in the OM images (Fig. 4d and Supplementary Fig. 19a). However, as shown in the AFM images, the pristine PTB7-Th film exhibits visible microcracks under a strain greater than 50% (Supplementary Fig. 19b), whereas no cracks are observed in the PTB7-Th/PDMS film even at a strain of 80% (Fig. 4e). This resilience is attributed to the elastic domains absorbing strain and minimizing stress in the fibrous networks, as schematically illustrated in Supplementary Fig. 2034.

The representative output and transfer characteristics, as well as the hysteresis behavior of the fabricated fully soft transistor, using the PTB7-Th/PDMS blend, are shown in Supplementary Figs. 21 and 22, which features typical p-channel characteristics. The confinement effect in the soft semiconductor, combined with the low contact resistance between the semiconductor and the electrode, synergistically contributes to the high performance of the fully soft organic transistor. These transistors exhibit an average μFE of 13.09 ± 4.17 cm2·V1·s1, and the highest μFE of 21.87 cm2·V1·s1 (Fig. 4f, g), surpassing the mobilities of previously reported fully soft organic transistors (Fig. 4h)17,29,31,35,36,37,38. The representative electrical characteristics of the device under various mechanical strains (0%, 20%, 50%, 80%, and after release to 0%) demonstrated its reliable operation (Fig. 4i–k and Supplementary Fig. 23). Notably, no physical damage or severe performance degradation was observed, even at an 80% strain both along and perpendicular to the LCH directions (Supplementary Fig. 24). It is worth mentioning that the μFE was calculated by considering channel geometry change under the strains. Under the mechanical strains applied along the LCH directions, μFE and VTH exhibited moderate changes from 16.15 cm2·V1·s1 at 0% to 11.51 cm2·V1·s1 at 80%, and from –2.33 V to –2.20 V, respectively. Upon completely releasing the mechanical strain, both the μFE and VTH returned to 15.36 cm²·V¹·s¹ and – 2.09 V, respectively. In the case of the device under strain perpendicular to the LCH direction, a similar trend was observed for both the μFE (14.04 cm2·V1·s1 at 0%, 7.42 cm2·V1·s1 at 80%, and 13.01 cm2·V1·s1 at 0% released) and VTH ( − 2.35 V at 0%, −2.33 V at 80%, and –2.36 V at 0% released) as with the strain along the LCH direction. To evaluate the durability of the fully soft transistor under mechanical stress, we further investigated its resistance to fatigue through repetitive stretching/releasing cycles of the device under a tensile strain of up to 80% in both along and perpendicular to the LCH direction. Figure 4l, m and Supplementary Fig. 25 show the representative transfer characteristics of the devices after 1000 cycles of stretching/releasing to an 80% strain, which notably demonstrated no significant performance degradation. Importantly, μFE and VTH showed only minor changes; μFE decreased from 14.15 cm2·V1·s1 to 10.05 cm2·V1·s1, and VTH shifted from –2.10 V to –2.24 V, following 1000 cycles of stretching/releasing along the LCH direction. Additionally, a similar trend was observed for cyclic stretching perpendicular to the LCH direction: μFE was changed from 13.18 cm2·V1·s1 to 8.54 cm2·V1·s1 and VTH from –2.36 V to –2.31 V after 1000 cycles. These results confirm the robust mechanical durability of the devices, maintaining their functional stability through extensive stress cycles. Supplementary Figure 26 presents the fully soft transistor undergoing various mechanical deformations, including stretching, bending, and twisting, exhibiting its adaptability. The use of all elastomeric materials in the devices ensures that the fully soft transistor can be deformed readily without sustaining physical damage. These results indicate that our approach, involving the addition of NaCl to the HAuCl4 solution for effective coating of the exposed AgNWs of the AgNWs/PDMS electrodes, provides a practical means to realize high-performance fully soft electronics.

Soft glucose sensors

Mechanical softness and chemical inertness are essential for bio-implantable devices39,40. Although the AgNWs/PDMS electrode has been employed in various bioelectronics5,41, its inherent vulnerability to chemical oxidation presents challenges for broader application. Specifically, implantable glucose sensors with a soft format, which monitor glucose concentrations in interstitial fluids, offer significant advantages for diabetes management due to the high correlation between blood and interstitial fluid glucose levels42. AgNWs/PDMS electrodes, while promising and useful, are not ideal for soft glucose sensors. This is because typical glucose sensors are enzymatic and involve the generation of H2O2 during glucose detection43, which adversely affects the stability of the AgNWs44. Therefore, our approach for the complete Au coating on the exposed AgNWs of the AgNWs/PDMS electrode significantly enhances its resistance to severe oxidation.

The soft glucose sensors were fabricated using uniformly Au-coated AgNWs/PDMS electrodes, prepared through galvanic replacement with HAuCl4 containing 50 mM NaCl. The sensor comprised an enzymatic sensing membrane and three electrodes: a working electrode (WE), a counter electrode (CE), and a reference electrode (RE) (Fig. 5a). Glucose oxidase (GOD) was used for the sensing membrane due to its specificity and stability45,46. The GOD layer was immobilized on the sensing electrode via hydrolysis with GOD and titanium isoperoxide, forming a particulate morphology similar to previous studies (Fig. 5b)45. EDX elemental mapping confirmed the well-formed GOD-titania sol-gel film (Supplementary Fig. 27). The detailed fabrication process of soft glucose sensors is described in the Experimental section. Immobilized GOD on the electrode accelerates D-glucose dissociation, generating H2O2, and consequently, electrons. Thus, the current measured by the sensor is determined by glucose concentration, as schematically illustrated in Fig. 5c and specifically described in Supplementary Note 3.

Fig. 5: Soft glucose sensors.
figure 5

a An optical image (left), and schematic exploded view (right) of the soft glucose sensors based on Au-coated AgNWs/PDMS electrodes galvanic replaced with 50 mM NaCl containing 0.5 mM HAuCl4 solution. b SEM image of the sensing area on the working electrode. c Schematic sensing mechanism of the glucose sensors. d Electrochemical stability of the AgNWs/PDMS and Au-coated AgNWs/PDMS electrodes in a 30 mM H2O2 solution. e Chronoamperometric current response of the soft glucose sensor at different glucose concentrations. f Calibration curve of the soft glucose sensor with a Michaelis-Menten model-based fitting curve. g Sensitivity of the soft glucose sensors. Optical images of the soft glucose sensors applicable as bio-implantable devices in the dermis (h), and on the liver (i). Inset in the (i) is the optical image without magnification.

The complete Au coating on the exposed AgNWs of the AgNWs/PDMS electrode, prepared using HAuCl4 containing NaCl, offers excellent electrochemical inertness. This property is crucial in oxidative environments, such as those involving H2O2. While AgNWs/PDMS electrodes show stability in mild environments (e.g., phosphate-buffered saline; PBS) (Supplementary Fig. 28), they are vulnerable to oxidation in oxidizing conditions. Figure 5d shows dramatic decrease in current flow for pristine AgNWs/PDMS under a 400 mV applied voltage in a 30 mM H2O2 solution. In contrast, electrodes with particulate Au coatings, prepared using HAuCl4 without NaCl, show a decline in current over time. However, those with a complete Au coating, prepared with NaCl in the HAuCl4 solution, exhibit negligible change. This stability is attributed to the prevention of electrochemical etching of Ag by H2O2 (Supplementary Fig. 29), indicating that complete Au coating on AgNWs/PDMS maintains electrical performance even in oxidative environments. Therefore, complete Au-coated AgNWs/PDMS represents an effective approach for enzyme-based soft glucose sensors.

A constant potential of 400 mV was applied to RE for chronoamperometric measurement of the glucose sensor across glucose concentrations ranging from 0 to 30 mM. This range adequately covers the normal and diabetic glucose levels in human interstitial fluid (approximately 2 to 23 mM)47. Figure 5e clearly shows the current response of the sensor to various glucose concentrations. Within the 0 to 15 mM range, the sensor exhibits a linear relationship between glucose concentration and measured current, with a sensitivity of 0.238 μA ∙ mM1∙cm2, and the limit of detection (LOD) of 0.498 mM (Supplementary Fig. 30, and Supplementary Note 4). Such sensing performance significantly outperforms that of the soft glucose sensor fabricated using an Au-coated AgNWs/PDMS electrode prepared via galvanic replacement without NaCl. In particular, the non-uniform Au coating exposes AgNWs to H2O2, leading to electrochemical degradation of the electrode, which results in unstable sensing capability and a low sensitivity of 0.168 μA ∙ mM1∙cm2 (Supplementary Fig. 31). The current response of the soft glucose sensor with uniformly Au-coated AgNWs/PDMS electrode, extending up to 50 mM was fitted using the Michaelis-Menten Kinetic model (Fig. 5f)48. The Michaelis-Menten constant (KM) and maximum current (IMAX) were 0.914 mM and 20.35 µA, respectively, as extracted from the Lineweaver-Burk plot (Supplementary Fig. 32). The detailed information is described in Supplementary Note 5. The sensor reliably maintains its sensing capability after seven days in PBS, as shown in Fig. 5g. This stability is attributed to the enhanced inertness provided by the complete Au coating on the electrode. Besides inertness, mechanical softness is a crucial attribute of our devices. Supplementary Fig. 33 shows the durability of the devices under various mechanical deformations, including bending and stretching. With these key features of inertness and softness, as well as biocompatibility of components49,50,51, the device exhibits significant potential as a bio-implantable solution. The successful conceptual demonstration of its conformal implantation both in the dermis and on the liver (Fig. 5h, i) underscores the ability of our work to address critical challenges, positioning it as a promising candidate for future bio-implantable devices.

Discussion

In this study, we have demonstrated a simple, effective, and reliable method for gold coating on AgNWs/PDMS electrodes, significantly advancing the field of soft electronics, including transistors and glucose sensors. We achieved uniform and complete Au coating on the exposed AgNWs of AgNWs/PDMS electrodes through galvanic replacement, facilitated by the addition of NaCl to the HAuCl4 solution. While a vigorous reaction with HAuCl4 solution leads to a non-uniform and particulate Au coating on the surface of AgNWs, adding NaCl to the HAuCl4 results in a uniform and complete Au coating. This is achieved by a slower reaction, which is a result of Le Chatelier’s principle and the change in reduction potential, coupled with the prevention of AgCl precipitation due to the presence of excess Cl. The uniform Au coating on the AgNW/PDMS electrodes significantly reduced RC with the organic semiconductor in PTB7-Th based organic transistors, thereby remarkably enhancing the electrical performance of these devices. Furthermore, the development of fully soft organic transistors with decreased RC and enhanced stretchability of PTB7-Th/PDMS highlights the potential of our approach in creating high-performance fully soft organic electronics. These advancements promise not only to revolutionize wearable technology but also to open new avenues in bio-implantable healthcare systems. The demonstrated soft glucose sensors, empowered by our complete Au-coated AgNWs/PDMS electrodes, exhibit significant electrochemical stability, paving the way for future bio-implantable devices.

Methods

Materials

Poly[4,8-bis(5-(2-ethylhexyl) thiophen-2-yl) benzo[1,2-b;4,5-b’]dithiophene-2,6-diyl-alt-(4-(2-ethylhexyl)-3-fluorothieno[3,4-b]thiophene)-2-carboxylate-2-6-diyl)] (PTB7-Th) was synthesized as previously reported31. Chloroform ( > 99%), gold chloride trihydrate (HAuCl4·3H2O; >99.9%), 1-Ethyl-3-methylimidazolium bis(trifluoromethylsulfonyl)imide (EMIM-TFSI), poly(vinylidene fluoride-co-hexafluoropropylene) (PVDF-co-HFP; molecular weight = ~ 400,000), poly(3-hexylthiophene-2,5-diyl) (P3HT; molecular weight = 50,000–100,000). D-(+)-glucose, glucose oxidase (GOD) from Aspergillus niger (Type X-S; 100,000–250,000 units/g solid), were purchased from Sigma-Aldrich, and used as received. Ammonia (NH4OH; 25.0–29.0%) was purchased from Duksan Chemicals. Acetone was purchased from Samchun Chemicals. Silver nanowires (AgNWs) solution (average diameter = 75–105 nm, average length = 40–80 µm, 1 wt% in IPA) was purchased from Kechuang. Polydimethylsiloxane (PDMS; Sylgard 184 silicone elastomer kit) was purchased from Dow-Corning. Titanium isopropoxide (98%) was purchased from Daejung Chemicals & Metals. Phosphate-Buffered Saline (10X, pH = 7.4) (PBS) was purchased from Invitrogen, which was diluted 10 times with ultra-pure water (CBW012) purchased from Dyne Bio for the experiment before use.

Preparation of AgNWs/PDMS electrode

For the preparation of the AgNWs/PDMS electrodes, the AgNWs were patterned by dropping AgNWs solution on a glass substrate with a polyimide tape-based shadow mask prepared by a programmable cutting machine (Silhouette Portrait 3), followed by drying at 60 °C for 10 min. Then, the shadow mask was detached from the substrate, and the patterned AgNWs were annealed at 200 °C for 20 min, which induced conductivity improvement. The channels were formed with razor blades subsequently for the fabrication of the organic transistors. Next, the degassed liquid phase PDMS (10:1 (w/w) pre-polymer/curing agent) was applied onto the patterned AgNWs by spin-casting at 250 rpm for 60 s, then solidified at 100 °C for 1 h. Due to the porous nature of the AgNWs network, liquid-phase PDMS can penetrate the pores of the networks, resulting in partially embedded AgNWs in PDMS. The solidified PDMS film was then carefully peeled off from the glass substrate to complete the preparation of AgNWs/PDMS electrodes.

Galvanic replacement process

The exposed AgNWs of AgNWs/PDMS electrodes were coated with Au by galvanic replacement. For the galvanic replacement, 0.5 mM HAuCl4 solutions containing different CNaCl (0, 10, 20, 50, 100, 200 mM) were used. The prepared solution was dropped on the desired area of the AgNWs/PDMS electrode, specifically on the channels, followed by keeping the sample at room temperature for various periods. Then, the Au-coated AgNWs/PDMS electrodes were rinsed with DI water and immersed in NH4OH for 1 min to remove the byproducts, AgCl, formed during the galvanic replacement. Finally, the fabrication of Au-coated AgNWs/PDMS electrodes was completed by washing with DI water, followed by blowing the remaining water away with N2 and dehydration at 90 °C for 10 min.

Preparation of organic semiconductor solution

The PTB7-Th solution was prepared by dissolving PTB7-Th in the chloroform (3 mg/ml) at 80 °C for 20 min. The P3HT solution was prepared by dissolving P3HT in the chloroform (5 mg/ml) at 60 °C for 20 min. The prepared PTB7-Th and P3HT solutions were used to fabricate the transistor to analyze various electrical characteristics. In the case of preparation of soft organic semiconductor solution, prepared 3 mg/ml PTB7-Th solution was blended with liquid-phase PDMS solution (10:1 (w/w) prepolymer/curing agent, 0.12 g/ml in chloroform) in a volume ratio of 10:1. The weight ratio between PTB7-Th and PDMS was 1:4 in the resultant solution.

Preparation of ion gel

To prepare ion gel dielectric, PVDF-co-HFP, dehydrated EMIM-TFSI, and acetone were mixed in a weight ratio of 1:4:7, followed by heating at 90 °C for 30 min. The homogeneously blended solution was dropped onto the cleaned glass substrate and solidified at 70 °C for 12 h in a vacuum oven. The solidified ion gel was cut into the desired shape using a razor blade.

Organic transistor fabrication

The fabrication of the transistors began with preparing patterned Au-coated AgNWs/PDMS electrodes. Then, PTB7-Th, P3HT, or PTB7-Th/PDMS was patterned by spin-casting (1500 rpm, 30 s) on the channel area of the electrodes with polyimide film-based shadow mask, followed by annealing of the sample at 120 °C for 20 min. It is noted that the retention time of the solution on the substrate before spin-casting is no longer than 1 s, which prevents swelling of the substrate by the solvent, chloroform. This short retention time, combined with the high volatility of chloroform and rapid spin speed, ensures the formation of a high-quality semiconducting film. Then, the prepared ion gel was laminated on top of the organic semiconductor and gate electrode to complete device fabrication.

Glucose sensor fabrication

The fabrication of the glucose sensors began with the preparation of patterned electrodes, Au-coated AgNWs/PDMS, using NaCl contained HAuCl4 solution for uniform Au coating. Following this, a pre-prepared solution of glucose oxidase (GOD) at a concentration of 10 mg/ml in PBS was delicately applied to the working electrode. To immobilize the GOD onto the electrode, the working electrode area was consistently exposed to a vapor of titanium isopropoxide solution for 8 h at room temperature. After this immobilization step, the sensor was thoroughly rinsed with ultrapure water to complete the fabrication process. The resulting glucose sensors were then stored in PBS at 4 °C, both before and after their characterization. This storage protocol ensures the stability and readiness of the sensors for subsequent analytical procedures.

Characterization

The cyclic voltammograms were obtained using a potentiostat (CHI 604E, CH Instruments) with three electrodes, including 3 mm glassy carbon, Pt wire, and Ag/AgCl (3 M NaCl) as working, counter, and reference electrodes, respectively. The surface morphologies, elemental mapping of AgNWs/PDMS electrodes, Au-coated AgNWs/PDMS electrodes, and GOD/titania were characterized by field emission scanning microscopy (SU7000, Hitachi) equipped with energy dispersive X-ray spectroscopy (EDAX element EDS system, Ametek). Atomic force microscopy (XE-100, Park Systems) was used to investigate the surface morphologies of organic semiconductors. The absorption spectra of the organic semiconductor film were obtained by spectrophotometer (V-670, JASCO). All the electrical performances were characterized by a semiconductor analyzer (4200-SCS, Keithley Instruments) with a probe station (MST 8000 C, MS Tech). The customized stretcher was additionally used for measuring device performance under mechanical strain.